GOSSEN LUNASIX MANUAL PDF


GOSSEN. GOSSEN. Erlangen. Attachment for. LUNASIX 3. Printed in Germany. e microphotographs. (The following instructions assume that you are. Here are all the pages of the operating manual for the Gossen Lunasix 3 photographic light meter. Lunasix light meters are also labelled Luna-Pro in some parts. You have an older device from GOSSEN? Here you can find the corresponding operating instructions for previous devices in the field of LUNASIX.

Author: Meztigar Daitaxe
Country: Slovenia
Language: English (Spanish)
Genre: Health and Food
Published (Last): 24 December 2004
Pages: 460
PDF File Size: 8.33 Mb
ePub File Size: 6.33 Mb
ISBN: 309-3-13749-890-9
Downloads: 65918
Price: Free* [*Free Regsitration Required]
Uploader: Nekinos

Share This Page Tweet. Incident light measurement at a substitute spot of equal illumination is also convenient for many regular outdoor scenes. You can read the pages one by one from the links below, or get the whole manual in pdf format you will need Acrobat Reader.

There are two answers to this question: I wondered what wrong with my Lunasix. Micro attachment The Lunasix meter can be used for photo-microscopy, by using the accessory Micro Attachment to fit the meter to a microscope. During the battery test, the indicator needle 14 should point to the red check mark The Lunasix F was positioned alongside the Lunasix and in turn was replaced by the Multisix.

This will help me to continue to host this site, buy new manuals, and pay their shipping costs. And, normally, the exposure indicated in this manner is perfectly correct. The built-in reflex finder with delineated “target” areas lets you pick out the exact portion to be measured. Pointer needle with mechanical computer Sensor: I’m afraid it sounds like it to me.

  COCOA BEACH MAP FILETYPE PDF

Gossen Lunasix Instruction Manuals

Null pointer ambient and flash meter Display: Where to manuap the users instruction manual for Gossen Lunasix? In the case of reflected light measurement, the LUNASIX 3 collects, within a certain angle, the light which is reflected from these many individual parts of the scene; it adds up all the light and strikes an average for which it indicates a suitable exposure time.

Wait again until the needle stops, and lock the reading in by releasing the selector. Built-in light lunasid instead of a mirror for greater accuracy and efficiency.

Exposure settings are then read from the computer dial, the lower window of which displays the measured EV “Exposure Value”. This camera manual gosse is for reference and historical purposes, all rights reserved.

For the amateur, especially the beginner, the over-all impression is usually decisive. Now, whenever the need arises, you can greatly expand the capabilities of the LUNASIX 3 by using one of the following exclusive accessory attachments: For black-and-white or colour negative films, this is usually a darker area which is to show details in the final print; for reversal colour slide or movie films, however, the lighter areas are usually favoured.

It is advisable to check the condition of the batteries from time to time, as follows: Fits the ocular tube of all microscopes for exact exposure determination.

Gossen Lunasix3 System exposure meter user manual, instruction booklet

Otherwise, determine by how much you need to increase or decrease future exposure readings to get the best results. Personal tools Log in. Make complete notes manua the readings and of any special conditions. The indicator needle should now rest on the check line to the left of the scale divisions The LUNASIX 3 is equipped with a spherical diffusing screen and thus achieves superior collection of the photographically effective illumination: While the element does not change its permanent properties under long exposure to light, it tends to retain the impression of light for a while.

  JOHN BAYLIS STEVE SMITH THE GLOBALIZATION OF WORLD POLITICS PDF

It permits you to measure very small areas of the projected image for maximum utilization of paper contrast and colour range.

Lunasix 3 manual

Analyze your prints and color transparencies for possible mistakes or errors in judgment. That’s especially important for close-up measurements. If the previous impression was “dark”, you can be sure of utmost measuring accuracy. This locks the reading in for convenient reference.

Naturally, neither the colour nor the brightness of the subject itself is considered by this measurement. Reflected light field luminance in footlamberts. That is the maximum the needle can reach to the left.

As an alternative to buying the Gossen adapter, Sarah Fox has made a web page with instructions for adjusting the meter to work with silver-oxide cells. Hi, Pete Many thanks for your advice and manuwl.

Therefore, keep an eye on such lighter areas and preferably expose a little shorter rather than longer, to get more brilliant colours. There are several advantages:. Ask your dealer for a demonstration!

It never reached to the check line zero line. Its microammeter indicates readings in ranges of, ft.